Return to Lopez Labs Home Page 
Return to Lopez Labs

 

Current Heater Testing at Lopez Labs

February 14, 1997 - Large Image Page

RUN No. HK-f27
 
 
Number of Pieces
8
Standard
Deviation
Total Weight, lb
52.6
1.68
Wood Moisture %
22.4
1.16
Fuel Surfac/Vol
3.05

Error:

Average Stack Temp, F
333.1

+/- 0.1

Average O2 %
15.72

+/- 0.2

Stack Dilution Factor
4.03
 
g/kg CO
26.32
estimated
Combustion Efficiency %
97.02
 
Heat Transfer Efficiency %
69.56
 
Overall Efficiency %
67.48

+/- 1.5

Average Output, 24 hrs, Kw

2.9

 

 
 
2 minutes
Kindling has different arrangnement,
some pieces in front of pile, left to right
5 minutes
10 minutes
15 minutes
1" air slot at bottom
of glass was closed after
this photograph
20 minutes 
25 minutes
30 minutes
 
 
40 minutes
50 minutes
60 minutes
70 minutes
80 minutes
90 minutes
100 minutes
110 minutes
120 minutes 

Compare with yesterday

0 minutes
 

This page last updated on April 8, 2003

Masonry Stove Builders Home Page