Return to Lopez Labs Home Page

2010 Heater Fuel Crib Tests at Shawville

Test HK-L07
January 21/10

Series 1: Test #1 of a 2 test pair with matched cribs. Warm heater.
Colorado M-4 (MHA Fueling Protocol) cribs spruce at 19.7% average moisture.
Loading factor 0.15 . Reload
3.75 lbs kindling + 24.0 lb crib (20.9% moisture) + reload w. 25.0 lb crib (18.4% moisture).
Efficiency is calculated at 95% oxygen recovery (Colorado method).
Stack temperature corrected for height.

Animation L07
Animation, 2 minute intervals.

gas analysis
Flue gas.

TESTO Excel data file


Condar Spreadsheet Results
Condar Spreadsheet Results

Condar Spreadsheet (includes detailed fueling data)

fuel load
First crib.

Detailed crib moisture data. The top 2 cribs were used for this test.

Burn sequence

This page was updated on February 8, 2010
This page was created on January 21, 2010