Test MHA-1714
January 26, 2017
Red oak, seasoned 3 years
Log cabin stacking, top ignition
62.0 lbs including 2.0 lbs kindling
19.6% moisture. 2334 stacking, see fuel photo
Pisla HTT 602 door, 22" wide
Austrian eco firebox, see http://www.heatkit.com/research/lopez-2014-03-01.html
Baffles from 2016 testing removed. Exit straight into raised ceiling:
In the last 2016 tests, the eco-air slots were partially blocked.
The blocks have been removed, adding approx 25% air.
Run #13 of a repeatability study with a new test fueling protocol under development
Condar spreadsheet results, calculated at 99 minutes.
With the eco-box, the test is over when the air supply is closed. Remaining charcoal would normally be burned in the next fire.
Lab Notes (to be added)
Testo gas graph.
Fuel load
Pieces are stacked in order of increasing weight.
This page was updated on February 4, 2017